Related to "gallium"

Description:

A multiuse fiber optic temperature sensor designed for a wide range of applications, especially for the use in R&D and industrial applications. The sensor offers complete immunity to RFI, EMI, NMR, Corrosive and microwave radiation making it the best choice for all demanding applications. The standard temperature sensor has a response time of 0.2 s. With a standard deviation of +/-0.2 °C it allows precise and repeatable measurements. The coating of the temperature sensor is made of PTFE, while the fiber tip has a diameter of 1.1mm and has a stainless steel ST-connector. For mechanical stability and applications e.g. in oil special protective coatings and hoses are available. The fiber optic probe consists of a PTFE protected glass fiber and a GaAs-crystal (Gallium Arsenide) at the sensor tip. It is totally free of metal and immune to external fields, therefore probes are explicitly suitable for use in high temperature ranges as well as in aggressive operating environments. The sensor cable can be from several meters to kilometers long without influencing the accuracy of the measurement result. Other sensor lengths and connector types are available upon request.

Related Keyphrases:

multiuse fiber optic temperature sensor | sensor offers complete immunity | standard temperature sensor | aggressive operating environments | oil special protective coatings | industrial applications | repeatable measurements | fiber optic probe | mechanical stability | high temperature | microwave radiation | standard deviation | measurement result | sensor lengths | connector types

Description:

A multiuse fiber optic temperature sensor designed for a wide range of applications, especially for the use in demanding applications. The sensor offers complete immunity to RFI, EMI, NMR and microwave radiation. The standard temperature sensor  has a response time of 0.2 s. With a standard deviation of +/-0.2 °C it allows for precise and repeatable measurements. The coating of the temperature sensor is made of PTFE, and the fiber tip has a diameter of 1.7 mm with Rugged Polyimide coating and has a stainless steel ST-connector. For mechanical stability and applications e.g. in oil special protective coatings and hoses are available. The fiber optic probe consists of a PTFE protected glass fiber and a GaAs-crystal (Gallium Arsenide) at the sensor tip. It is totally free of metal and immune to external fields, therefore probes are explicitly suitable for the use in high temperature ranges as well as in aggressive operating environments. The sensor cable can be from  several meters to kilometers long without influencing the accuracy of the measurement result. Other sensor lengths and connector types are available upon request.

Related Keyphrases:

multiuse fiber optic temperature sensor | standard temperature sensor | aggressive operating environments | oil special protective coatings | repeatable measurements | fiber optic probe | mechanical stability | high temperature | standard deviation | measurement result | sensor lengths | complete immunity | sensor cable | connector types | Gallium Arsenide

Description:

A multiuse fiber optic temperature sensor designed for a wide range of applications, especially for the use in demanding applications. The sensor offers complete immunity to RFI, EMI, NMR and microwave radiation. The standard temperature sensor has a response time of 0.2 s. With a standard deviation of +/-0.2 °C it allows precise and repeatable measurements. The coating of the temperature sensor is made of PTFE, and the fiber tip has  0.3 mm x 0.3 mm area with a Polyimide coating. The fiber optic probe consists of a PTFE protected glass fiber and a GaAs-crystal (Gallium Arsenide) at the sensor tip. It is totally free of metal and is immune to external fields. Therefore, the probes are explicitly suitable for use in large temperature ranges as well as in aggressive operating environments. The sensor length can be from several meters to 1 kilometer in length without impacting the accuracy of the measurement result. Other sensor lengths and connector types are available upon request.

Related Keyphrases:

multiuse fiber optic temperature sensor | standard temperature sensor | aggressive operating environments | repeatable measurements | fiber optic probe | large temperature | standard deviation | measurement result | sensor lengths | complete immunity | Gallium Arsenide | external fields | connector types | sensor tip | several meters

Description:

A multiuse fiber optic temperature sensor designed for a wide range of applications, especially for the use in demanding applications. The sensor offers complete immunity to RFI, EMI, NMR and microwave radiation. The standard temperature sensor has a response time of 0.2 s. With a standard deviation of +/-0.2 °C it allows precise and repeatable measurements. The coating of the temperature sensor is made of PTFE, and the fiber tip has  0.3 mm x 0.3 mm area with a Polyimide coating. The fiber optic probe consists of a PTFE protected glass fiber and a GaAs-crystal (Gallium Arsenide) at the sensor tip. It is totally free of metal and is immune to external fields. Therefore, the probes are explicitly suitable for use in large temperature ranges as well as in aggressive operating environments. The sensor length can be from several meters to 1 kilometer in length without impacting the accuracy of the measurement result. Other sensor lengths and connector types are available upon request.

Related Keyphrases:

multiuse fiber optic temperature sensor | standard temperature sensor | aggressive operating environments | repeatable measurements | fiber optic probe | large temperature | standard deviation | measurement result | sensor lengths | complete immunity | Gallium Arsenide | external fields | connector types | sensor tip | several meters

Description:

A multiuse fiber optic temperature sensor designed for a wide range of applications, especially for the use in demanding applications. The sensor offers complete immunity to RFI, EMI, NMR and microwave radiation. The standard temperature sensor has a response time of 0.2 s. With a standard deviation of +/-0.2 °C it allows precise and repeatable measurements. The coating of the temperature sensor is made of PTFE, and the fiber tip has  0.3 mm x 0.3 mm area with a Polyimide coating. The fiber optic probe consists of a PTFE protected glass fiber and a GaAs-crystal (Gallium Arsenide) at the sensor tip. It is totally free of metal and is immune to external fields. Therefore, the probes are explicitly suitable for use in large temperature ranges as well as in aggressive operating environments. The sensor length can be from several meters to 1 kilometer in length without impacting the accuracy of the measurement result. Other sensor lengths and connector types are available upon request.

Related Keyphrases:

multiuse fiber optic temperature sensor | standard temperature sensor | aggressive operating environments | repeatable measurements | fiber optic probe | large temperature | standard deviation | measurement result | sensor lengths | complete immunity | Gallium Arsenide | external fields | connector types | sensor tip | several meters

Description:

A multi use fiber optic temperature sensor designed for a wide range of applications, especially for the use in demanding applications, Sensor offers complete immunity to RFI, EMI, NMR and microwave radiation. The standard temperature sensor has a response time of 0.2s. With a standard deviation of +/-0.2°C it allows precise and repeatable measurements. The coating of temperature sensor is made of PTFE, the fiber tip has a diameter of 0.7mm with Polyimid coating and has a stainless steel ST-connector. For mechanical stability and applications e.g. in oil special protective coatings and hoses are available. The fiber optic probe consists of a PTFE protected glass fiber and a GaAs-crystal (Gallium Arsenide) at the sensor tip. It is totally free of metal and immune to external fields, therefore probes are explicit suitable for the use in high temperature ranges as well as in aggressive operating environments. The sensor cable can be from several meters to kilometers long without influencing the accuracy of the measurement result. Other sensor lengths and connector types are available upon request.

Related Keyphrases:

multi use fiber optic temperature sensor | standard temperature sensor | aggressive operating environments | oil special protective coatings | repeatable measurements | fiber optic probe | mechanical stability | high temperature | standard deviation | measurement result | complete immunity | sensor lengths | connector types | Gallium Arsenide | external fields