Get Quote
 banner
Home Solutions
SOLUTION'S SUMMARY
RELATED PRODUCTS
O201
Specifications
Measurement Range-80 °C to +300 °C (cryogenic 4 °K range optional)
Measurement range (Optional Range extensions)Down to 4 °K / Up to +300 °C
Resolution0.1°C
Accuracy±1.0 °C (+/- 0.2 °C in relative temperature)
Number of Channels1 - 8 Channels
USB (to use with Rugged connect windows software)1 sec interval on USB / Micro SD card
Config portUSB (to use with Rugged connect windows software)
LSENSU
Specifications
Temperature range-200 °C to +250 °C
Measurement range (Optional Range extensions) Down to 4 °K / Up to +300 °C
Repeatability0.2 °C
Accuracy absolute temperature+/- 0.8 °C
Accuracy relative temperature+/- 0.2 °C
Probe sheathing materialTeflon Coated
ConnectorStainless Alloy / Optional - Dielectric
H201
Specifications
Measurement Range-80 °C to +300 °C
Measurement range (Optional Range extensions) Down to 4 °K / Up to +300 °C
Resolution0.1°C
Accuracy±1.0 °C (+/- 0.2 °C in relative temperature)
Number of Channels 2 - 8 Channels
Scan rate200 ms / channel
Logging1 sec interval on USB
R501
Specifications
Measurement Range-80 °C to +300 °C (cryogenic 4 °K range optional)
Resolution0.1 °C
Accuracy±1.0 °C (±0.2 °C in relative temperature)
Scan Rate200 ms / channel ( Optional: Faster scanning rates available)
Number of Channels2, 4, 6 and 8 channels
Serail PortRS485 with Modbus support
CANBUS PortCANBUS Master/Slave support for CAN Dataloggers
TSENS
Specifications
Temperature range-200 °C to +250 °C
Repeatability0.2 °C
Accuracy absolute temperature+/- 0.8 °C
Accuracy relative temperature+/- 0.2 °C
Probe sheathing materialTeflon spiral-wrap
Tip materialTorlon (with disc) or Polyimide (no disc)
ConnectorStainless Alloy ST / Optional - Dielectric Torlon
LSENST
Specifications
Temperature range-200 °C to +250 °C
Temperature range (Optional Range extensions) RepeatabilityDown to 4 °K / Up to +300 °C
Repeatability0.2 °C
Accuracy absolute temperature+/- 0.8 °C
Accuracy relative temperature+/- 0.2 °C
Probe sheathing materialTeflon Coated
ConnectorStainless Alloy / Optional - Dielectric
LSENSR
Specifications
Temperature range-200 °C to +250 °C
Temperature range (Optional Range extensions) Down to 4 °K / Up to +300 °C
Repeatability0.2 °C
Accuracy absolute temperature+/- 0.8 °C
Accuracy relative temperature+/- 0.2 °C
Probe sheathing materialTeflon Coated, Rugged Polyimide protection for sensor tip
ConnectorStainless Alloy / Optional - Dielectric
LSENSP
Specifications
Temperature range-200 °C to +250 °C
Temperature range (Optional Range extensions) Down to 4 °K / Up to +300 °C
Repeatability0.2 °C
Accuracy absolute temperature+/- 0.8 °C
Accuracy relative temperature+/- 0.2 °C
Probe sheathing materialTeflon Coated, with Polyimide protection for sensor tip
ConnectorStainless Alloy / Optional - Dielectric
LSENSC
Specifications
Temperature rangeDown to 4 °K / Up to +85 °C
Repeatability0.2 °C
Accuracy absolute temperature+/- 0.8 °C
Accuracy relative temperature+/- 0.2 °C
Probe sheathing materialTeflon Coated, except for the sensor tip
ConnectorStainless Alloy / Optional - Dielectric
Response timeUp to 0.2 Sec
LSENSB
Specifications
Temperature range-200 °C to +250 °C
Temperature range (Optional Range extensions) Down to 4 °K / Up to +300 °C
Repeatability0.2 °C
Accuracy absolute temperature+/- 0.8 °C
Accuracy relative temperature+/- 0.2 °C
Probe sheathing materialTeflon Coated, except for the sensor tip
ConnectorStainless Alloy / Optional - Dielectric
HPM601-C
Specifications
SoftwareRugged Enterprise
Dimensions260mm(L) x 310mm(W) x 120mm(H)
Synchronization Inputs 2 Inputs, Software Selectable (Internal & External)
Input Power35W Max
Ambient Temperature-30C - 60C
Storage Temperature-40C - 85C
IP Rating IP65
Hsens-T
Specifications
TypeIntegrated magnets help it to attach to metalclad switchgear
Frequency Response (-6dB)1 MHz - 100 MHz
MaterialRugged plastic (Black), other options available
Signal Cable TypeRG223
Signal Cable ConnectorsCable gland (Sensor End) and TNC connector (Monitor End), other options available
Signal Cable length5m as standard, other options available
IP RatingIP65
HPM601-P
Specifications
Channels4 Simultaneous channels
Sampling Rate250 MS/s
FilteringSoftware configurable band pass filters
Bandwidth0.01 - 100 MHz
AmplificationUpto 50 dB, Software selectable
SSD Storage Memory1 TB Industrial Grade SSD
Data Transfer High Resolution 10,000 pulses per second for 4 simultaneous channels
HSENS-H
Specifications
TypeSplit core
Typical Frequency Response (-6dB)100 KHz - 25 MHz
MaterialRugged plastic (Black), other options available
Current Ratings50A , other options available
HFCT-3220mm (L) x 118mm (W) x 33mm (H) (ID = 30mm)
HFCT-5220mm (L) x 163mm (W) x 28mm (H) (ID = 50mm)
HFCT-9265mm (L) x 200mm (W) x 38mm (H) (ID = 90mm)

R-CONNECT

rconnect

Rugged connect provides remote visualization of temperature and other data being measured / monitored by various rugged monitoring systems. The software can connect to multiple monitoring devices for data collection and advance visualization. The intuitive user interface of the software is designed to give quick access to the most relevant information with highest level of data security.

  •  Cyber Security
  •  Real-time Data
  •  Data Logging
  •  Health Check