Dissolved Gas Analysis (DGA) in Transformers: Online vs Offline Methods and Why It Matters

Share
Listen to This Article

Dissolved Gas Analysis in transformers is one of the crucial techniques for detecting developing faults before they cause major failures. Every transformer undergoes thermal, electrical, and mechanical stress during its operation.  Each of these events causes the formation of gases within the transformer’s insulating oil, affecting the stability and safety of the entire power grid.

By analyzing these gases, engineers can understand what’s happening inside the transformer without opening it up. But how should this analysis be performed? Perhaps through offline laboratory testing or online dissolved gas analysis of the transformer oil.

Let’s explore both methods and understand which method is becoming the benchmark for advanced transformer monitoring.

What is Dissolved Gas Analysis in transformers?

DGA is a diagnostic technique used to assess transformer health by analyzing the gases dissolved in its insulating oil. By studying the type and concentration of these gases, valuable insights can be gained about the overall condition of the transformer. The IEC standard for DGA provides a reliable framework for interpreting gas levels, helping operators pinpoint issues such as partial discharges, overheating, or even electrical arcing inside the unit.

During testing, DGA typically examines key gases, including Hydrogen (H2), Carbon Monoxide (CO), Ethane (C2H6), Methane (CH4), Carbon Dioxide (CO2), Ethylene (C2H4), Oxygen (O2), and Acetylene (C2H2). Collectively, these gases are known as diagnostic gases. Each of these gases indicates specific fault conditions. For instance,

  • Hydrogen indicates the partial discharge
  • Methane gas generally indicates partial discharge activity and overheating of oil
  • Ethylene is linked to hotspot or localized overheating
  • Acetylene indicates high-energy arcing
  • Carbon Monoxide represents the aging or thermal decomposition of a transformer’s cellulose insulation
  • Carbon Dioxide indicates overheating of the paper
  • Oxygen is present due to residual air or air ingress into the transformer

Protection devices such as Buchholz relays have been used to detect catastrophic faults in oil-filled transformers. However, these devices are not efficient in identifying substantial failures, as they are unable to capture the minor gas patterns that indicate developing issues. This highlights the importance of analyzing the gases dissolved in transformer oil.

Dissolved Gas Analysis Monitoring Methods in Transformers

The two main categories of DGA monitoring techniques are:

  1. Offline (lab-based)
  2. Online (continuous monitoring)

Each has distinct advantages, limitations, and appropriate use cases.

What is Offline Dissolved Gas Analysis in Transformers?

Offline DGA, also known as laboratory dissolved gas analysis of transformer oil. It is a traditional and accurate method that has been used for decades. In this process, a technician collects a sample of transformer oil, seals it in a syringe or container, and sends it to a laboratory for analysis. Inside the lab, gases are extracted from the oil using techniques such as headspace gas extraction and analyzed through gas chromatography (GC).

For gas chromatography, IEC 60599:2015 and IEEE C57.104-2019 provide interpretation guidelines for dissolved gas levels in offline samples. GC delivers high precision and can measure even trace amounts of gases at parts per million (ppm) levels.

Pros of Offline DGA

  • Detects all critical fault gases with precision.
  • Suitable for forensic and deep-dive analysis of complex faults.

Cons:

  • Requires transformer shutdown and manual sampling.
  • Time-consuming and logistically intensive.
  • Typically performed once or twice a year, leaving long gaps between data points.
  • Sensitive to environmental variations; GC systems need daily calibration.

Overall, Offline DGA is a reliable method for scheduled maintenance; however, it lacks the speed and consistency required for continuous fault prevention.

What is Online Dissolved Gas Analysis in Transformers?

With advances in digitalization, online DGA monitors have been gaining popularity. These devices provide real-time fault detection and predictive insights without interrupting operation.

Modern online DGA analyzers continuously sample oil, detect dissolved gases and transmit data remotely. The systems are based on compact and automated versions of laboratory GC systems. Online GC provides accurate measurement of gas concentrations and trends, allowing for comparison with historical data and maintaining superior accuracy through its frequent self-calibration. This ensures consistent performance and allows predictive maintenance.

However, other method, such as Photo-Acoustic Spectroscopy (PAS), detect gases through the photo-acoustic effect. By analyzing the sound at different wavelengths, a photoacoustic spectrum is generated. This allows the identification of specific fault gases. PAS does not require a carrier gas, making the system cost-effective in the long run.

Pros of Online DGA:

  • Continuous, real-time monitoring of DGA in transformers without power shutdown.
  • Immune to temperature, vibration, and pressure changes.
  • No frequent servicing required.
  • Enables early fault detection and predictive maintenance.

Cons:

  • Higher initial cost than occasional lab tests.

With online DGA analysis, utilities can track daily, weekly, and seasonal gas trends. They can identify trends, patterns, and prevent failures long before they occur.

Choosing between Online and Offline Monitoring Methods

The decision depends on several factors, such as:

Criteria Offline DGA in transformers Online DGA in transformers
Operation Requires shutdown Continuous, real-time monitoring
Accuracy  High in lab conditions High, field-stable
Frequency Periodic (annual/bi-annual) Continuous (daily or weekly)
Maintenance Needs manual sampling Automated, maintenance-free

In practice, many utilities combine both approaches. Online DGA monitoring provides real-time condition monitoring, while offline DGA is used for periodic testing.

Is Online DGA Monitoring the Smarter Choice Today?

In power networks, shutting down transformer operations and waiting for lab results is often an inefficient approach. That’s why many operators prefer online DGA monitoring, which offers several distinct advantages:

Continuous Monitoring: Detects faults as soon as they develop, not months later. This enables operators to receive early warnings and take any necessary action in a timely manner.

Cost Saving: DGA monitoring enables operators to adopt condition-based maintenance. Prevents catastrophic failure and reduces maintenance costs for utilities that require replacement.

Early Fault Detection: By identifying potential issues such as overheating, arcing, and insulation degradation, DGA monitoring helps to extend the transformer’s lifespan.

Remote Access: Online DGA monitoring allows operators to view results remotely, eliminating the need for physical presence at the site.

Improved Reliability and Safety: Enables proactive maintenance, reducing unexpected shutdowns and mitigating risk to ensure safer transformer operation.

Compliance with Industry standards: For DGA transformer monitoring, standards from organizations like IEEE and IEC recommend regular testing. Following these standards helps transformers operate safely and reliably.

Switching Towards Predictive Reliability

A single gas reading may not raise alarms, but a steady rise in concentration can indicate an emerging fault. This highlights the need for predictive monitoring rather than reactive checks.

However, Traditional lab-based DGA relies on periodic oil sampling, leading to delays, contamination risks, and monitoring gaps that limit its effectiveness in failure prevention. To overcome these challenges, Rugged Monitoring’s RM EYE enables utilities to transition from reactive diagnostics to real-time, predictive maintenance. By applying AI-driven analytics, advanced digitization, and automated diagnostics, it ensures continuous transformer health monitoring, helping operators detect failures early, optimize maintenance, and reduce costs.

Stay ahead of failures and ensure optimal transformer performance with Rugged Monitoring!